Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06
1
Models:
Pier-HV-IPI
ST-HV-IPI
LCOR-HV-IPI
RCOR-HV-IPI
In the Commonwealth of Massachusetts:
installation must be performed by a licensed
plumber or gas fitter;
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
Please contact your Heat & Glo dealer with any
questions or concerns. For the location of your nearest
Heat & Glo dealer, please visit www.heatnglo.com.
Printed in U.S.A. Copyright 2006
Heat & Glo, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
Owners Manual
Installation and Operation
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471,
5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165,
6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802,
6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250,
780403, 1418504 or other U.S. and foreign patents pending.
Seitenansicht 0
1 2 3 4 5 6 ... 44 45

Inhaltsverzeichnis

Seite 1 - Owner’s Manual

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/061Models:Pier-HV-IPIST-HV-IPILCOR-HV-IPIRCOR-HV-IPIIn the C

Seite 2

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0610Part number list on following page.7 Log Assembly(NG, LP)

Seite 3 - Table of Contents

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0611Service Parts List (NG, LP)IMPORTANT: THIS IS DATED INFO

Seite 4 - Pier-HV-IPI

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0612(NG, LP) Exploded Parts DiagramService PartsL&RCOR-H

Seite 5 - PIER-HV-IPI

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0613Appliance CertificationThe Heat & Glo fireplace mode

Seite 6 - ST-HV-IPI

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0614For all side wall horizontally vented gas fueled equipmen

Seite 7

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06152Getting StartedIntroducing the Heat & Glo Gas Firep

Seite 8 - LCOR-HV-IPI

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0616Figure 1. Diagram of the PIER-HV-IPI5-1/4(133mm)1/2(13mm)

Seite 9

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0617Figure 2. Diagram of the ST-HV-IPI5-14(133mm)12(306mm)1/

Seite 10 - RCOR-HV-IPI

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0618Figure 3. Diagram of the LCOR-HV-IPI and RCOR-HV-IPI5-1/4

Seite 11 - Service Parts List (NG, LP)

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06193Installing the FireplaceStep 1. Locating the Fireplace

Seite 12 - Service Parts

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/062These units MUST use one of the vent systemsdescribed in t

Seite 13 - Approvals and

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0620Minimum Clearances from the Fireplace to Combustible Mate

Seite 14 - Massachusetts

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0621Framing should beconstructed of 2 X 4lumber or heavier.M

Seite 15 - Getting Started

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0622NOTE: PIPES OVERLAP 1-1/4 INCHESAT EACH JOINT.Figure 6.

Seite 16

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0623Figure 7. Vent System Components and Termination KitsSte

Seite 17

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0624Figure 8NOTE: On vertical ventingconfigurations you maywa

Seite 18

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0625Figure 14. Venting with One 90° ElbowFigure 13. Venting

Seite 19 - 47-1/2 in

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0626Figure 15. Venting with Two 90° ElbowsH1HVVV1HNATURAL GAS

Seite 20

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0627Figure 16.Venting with Two 90° ElbowsFigure 17. Venting

Seite 21 - Model A B C D E

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0628Figure 18. Venting with three 90° elbowsHH1H2V HVH1V1NA

Seite 22 - AT EACH JOINT

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0629Figure 19. Venting with three 90° elbowsVHH1V1VHH1V 1NAT

Seite 23 - DVP-TRAP

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/063Table of ContentsSafety and Warning Information...

Seite 24 - - CHART

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06301. Attach the First Vent Component to the Starting Coll

Seite 25

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06314. Install FirestopsFor Horizontal Runs - Firestops are

Seite 26

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0632Figure 26. Ceiling Firestop (Ceiling Side)If the area ab

Seite 27

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0633V= VENT TERMINALX= AIR SUPPLY INLET= AREA WHERE TERMINA

Seite 28

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0634For Vertical Terminations - To locate the vent and instal

Seite 29

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0635Step 4. Positioning, Leveling, and Securingthe Fireplac

Seite 30 - FRONT VIEW

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0636• Insert insulation from the outside of the fireplace and

Seite 31 - 12"

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0637Step 8. Wiring the FireplaceNOTE: Electrical wiring mus

Seite 32 - 7 1/4"

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0638Wall SwitchPosition the wall switch in the desired positi

Seite 33 - (See Note 5)

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0639If the box is being wired to a wall mounted switch for u

Seite 34

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0646 Log Assembly(NG, LP) Exploded Parts DiagramService Part

Seite 35 - IPI PILOT

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0640Step 9. FinishingFigures 39 and 40 show the minimum vert

Seite 36 - Step 6. The Gas Supply Line

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0641Installing the TrimCombustible materials may be brought

Seite 37 - ELECTRIC EMBERS

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0642Now the Lava rock can be applied (see Figure 45).Figure 4

Seite 38 - C rated wire

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0643Placing the Ember MaterialEmber material is shipped with

Seite 39

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/0644Step 11. Before Lighting the FireplaceBefore lighting t

Seite 40 - Step 9. Finishing

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06454Maintaining and Servicing Your FireplaceFireplace Maint

Seite 41 - L&RCOR-HV-IPI TEMPERED

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/065AVAIL AB LETO SHIP IN 24HOURSITEM DESCRIPTION SERIAL # PA

Seite 42

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/066(NG, LP) Exploded Parts DiagramService PartsST-HV-IPIBegi

Seite 43 - ACCESS PANEL

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/067AVAILABLE TOSHIP IN 24HOURSITEM DESCRIPTION SERIAL # PART

Seite 44 - After the Installation

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/068Part number list on following page.7 Log Assembly15(NG, LP

Seite 45 - Fireplace Maintenance

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/069AVAILABLE TOSHIP IN 24HOURSITEM COMMON PARTS SERIAL # PA