Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 1
Models:
8000CF-OAK-IPI
8000CFLP-OAKIPI
DO NOT store or use gasoline or other am-
mable vapors and liquids in the vicinity of this
or any other appliance.
What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli-
er’s instructions.
- If you cannot reach your gas supplier, call
the re department.
Installation and service must be performed
by a quali ed installer, service agency, or the
gas supplier.
WARNING: If the information in these
instructions is not followed exactly, a re
or explosion may result causing property
damage, personal injury, or death.
Owners Manual
Installation and Operation
DO NOT DISCARD THIS MANUAL
NOTICE
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer’s instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
Installation and service of this appliance should be
performed by quali ed personnel. Hearth & Home
Technologies suggests NFI certi ed or factory trained
professionals, or technicians supervised by an NFI
certi ed professional.
Leave this manual with
party responsible for use
and operation.
DO NOT
DISCARD
WARNING
Important operating
and maintenance
instructions included.
Read, understand and follow
these instructions for safe
installation and operation.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
This appliance has been supplied with an integral barrier
to prevent direct contact with the xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
DO NOT touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
replace.
Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other ammable
materials.
Keep clothing, furniture, draperies and other ammable
materials away.
Para obtener un ejemplar en Español de este
Manual del propietario, visite www.heatnglo.com.
Pour demander un exemplaire en français de ce Manuel
du propriétaire, visitez www.heatnglo.com.
Î
Seitenansicht 0
1 2 3 4 5 6 ... 57 58

Inhaltsverzeichnis

Seite 1 - Owner’s Manual

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 1Models:8000CF-OAK-IPI8000CFLP-OAKIPI• DO NOT store or use gasoline or other fl am-mabl

Seite 2 - A. Congratulations

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0910D. Clear SpaceWARNING! DO NOT place combustible objects in front of the fi replace or

Seite 3 - User Guide

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 11I. Lighting Instructions (IPI)The IPI system may be operated with two D-cell batter

Seite 4

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0912Initial Break-in Procedure• The fireplace should be run three to four hours

Seite 5 - B. Limited Lifetime Warranty

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 13Glass CleaningFrequency: SeasonallyBy: HomeownerTools Needed: Protective gloves,

Seite 6

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0914VentingFrequency: SeasonallyBy: HomeownerTools needed: Protective gloves and safety

Seite 7 - Listing and Code Approvals

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 15(Either cobrahead or SIT)Figure 3.1 IPI Pilot Flame Patterns

Seite 8 - Massachusetts

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0916A. Typical Appliance SystemNOTICE: Illustrations and photos refl ect typical installa

Seite 9

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 17B. Design and Installation ConsiderationsHeat & Glo direct vent gas appli

Seite 10 - 3 FT. IN FRONT OF FIREPLACE

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09185Framing and Clearances A. Selecting Appliance LocationWhen selecting a location f

Seite 11 - WARNING:

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 19CBDAB. Constructing the Appliance ChaseA chase is a vertical box-like structure bui

Seite 12 - J. After Fireplace is Lit

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/092Listing Label Information/LocationModel Name: ________________________________________

Seite 13 - Maintenance and Service

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0920D. Mantel and Wall ProjectionsWARNING! Risk of Fire! Comply with all minimum clear-a

Seite 14

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 21A. Vent Termination Minimum ClearancesRoof Pitch H (Min.) Ft.Flat to 6/12...

Seite 15 - (Either cobrahead or SIT)

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0922ONPRQV= VENT TERMINALX= AIR SUPPLY INLET= AREA WHERE TERMINAL IS NOT PERMITTEDFigure

Seite 16 - Installer Guide

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 23A. Approved PipeThis appliance is approved for use with Hearth & Home Technolog

Seite 17 - C. Tools and Supplies Needed

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0924INSTALLEDHORIZONTALLYH1H2V1H1V1Figure 7.3Figure 7.4One ElbowTwo ElbowsTop Vent - Hori

Seite 18 - Framing and Clearances

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 25Figure 7.5Top Vent - Horizontal Termination - (continued)Three ElbowsH2H1V2V1V1 Min

Seite 19 - C. Clearances

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0926Top Vent - Vertical TerminationNo ElbowFigure 7.6Note: If installing a vertical vent/

Seite 20 - Dimensions of Combustibles

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 27Figure 7.11Two ElbowsH1V1V2V1H1 Maximum V2V1 + V2 Minimum1 ft. 305 mm 3 ft. 914 mm

Seite 21 - Termination Locations

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0928A. Pipe Clearances to CombustiblesWARNING! Risk of Fire! Maintain air space clearanc

Seite 22 - Covered Alcove Applications

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 29A12 in.10 in.BFigure 8.6 Wall PenetrationB. Wall Penetration FramingA* B 57-1/2

Seite 23 - 8-1/2 in

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 3 Safety Alert Key:• DANGER! Indicates a hazardous situation which, if not avoided

Seite 24 - Figure 7.4

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0930C. Install the Ceiling FirestopA ceiling fi restop MUST be used between fl oors

Seite 25 - Figure 7.5

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 31D. Install Attic Insulation ShieldWARNING! Fire Risk. DO NOT allow loose materials

Seite 26 - 1 2 3 4 5

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0932A. Attaching Sheetrock LedgesAttach sheetrock ledges together using the attach

Seite 27 - Figure 7.12

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 33C. Securing and Leveling the ApplianceWARNING! Risk of Fire! Prevent contact with:•

Seite 28 - Figure 8.4

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0934PILOTPLATEFigure 9.8Note: Ensure pilot plate is in place. This will ensure

Seite 29 - B. Wall Penetration Framing

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 3510 Installing Vent Pipe A. Assemble Vent SectionsAttach Vent to the Firebox Assem

Seite 30

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0936B. Assemble Slip Sections• Slide the inner fl ue of the slip section into the inner

Seite 31

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 37D. Disassemble Vent Sections• Rotate either section (see Figure 10.9) so the

Seite 32 - B. Temporary Access Panel

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0938E. Install Metal Roof Flashing• See minimum vent heights for various pitched

Seite 33 - Figure 9.5 Fiberglass Gasket

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 39SCREWSCAULKSTORM COLLAR(1 of 3)Figure 10.15 TERMINATION CAPG. Install Vertical Term

Seite 34 - E. Completing Grate Set-up

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/094Î = Contains updated information.13 Finishing A. Mantel and Wall Projections . . .

Seite 35 - Installing Vent Pipe

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0940Figure 10.16 Venting through the wallINTERIORHEAT SHIELD OREXTENDEDHEAT SHIELDWALL SH

Seite 36 - C. Secure the Vent Sections

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 41A. Fuel Conversion• Make sure the appliance is compatible with available gas types

Seite 37 - D. Disassemble Vent Sections

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0942A. Wiring RequirementsNOTICE: This appliance must be electrically wired and grounded

Seite 38

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 43D. Electrical Service and RepairWARNING! Risk of Shock! Label all wires prior to di

Seite 39 - Termination

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0944F. Wall Switch Installation for Fan (Optional)If the box is being wired to a wall mo

Seite 40 - Cap Specifi cation Chart

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 45A. Mantel and Wall ProjectionsWARNING! Risk of Fire! Comply with all minimum clear-

Seite 41 - Gas Information

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0946124678109A. Remove Fixed Glass AssemblySee Section 14.I.B. Remove the Shipping Mate

Seite 42 - Electrical Information

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 47G. Ember PlacementWARNING! Risk of Explosion! Follow ember placement instructions i

Seite 43

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0948H. Install the Log AssemblyLog Assembly: LOGS-8OAKIf the gas logs have been factory

Seite 44 - E. Junction Box Installation

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 49STEP 5: (SRV2057-723): Mate the top of log 4 with the right metal tab on log 3. The

Seite 45 - Finishing

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 5B. Limited Lifetime WarrantyÎ

Seite 46 - Appliance Setup

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0950M. Air Shutter SettingAir shutter settings should be adjusted by a qualifi ed ser-vice

Seite 47 - G. Ember Placement

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 5115 Troubleshooting With proper installation, operation, and maintenance your gas a

Seite 48 - Log Assembly: LOGS-8OAK

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0952Intellifi re Ignition System - (continued)Symptom Possible Cause Corrective Action4. P

Seite 49 - NOTE: Finished top view

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 5316 Reference Materials A. Appliance Dimension DiagramDimensions are actual applia

Seite 50 - K. Hood

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/0954B. Vent Components DiagramsFigure 16.2 DVP vent components 10-1/2 in.(267 mm)10-7/8

Seite 51 - Troubleshooting

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 55DVP-TRAP1DVP-TRAP2DVP-TRAPK2DVP-TRAPK1DVP-TRAPHorizontal Termination Cap15-1/8 in.(3

Seite 52

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/095613-1/4 in.(367 mm)24-5/8 in.(625 mm)27-1/2 in.(127 mm)RF6MRoof Flashing Multi-pak31 i

Seite 53 - Reference Materials

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 57DVP-TB1BasementVent Cap12 in.(305 mm)1-1/2 in.(38 mm)7-3/8 in.(187 mm)14 in.(356 mm)

Seite 54 - B. Vent Components Diagrams

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 61Heat & Glo, a brand of Hearth & Home Technologies Inc. 7571 215th St, Lakevi

Seite 55 - DVP-TRAPK1

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/096B. Limited Lifetime Warranty (continued)

Seite 56

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 7B. Tempered Glass Specifi cationsHearth & Home Technologies appliances manuf

Seite 57

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/098H. Requirements for the Commonwealth of MassachusettsFor all side wall horizontally

Seite 58 - DO NOT DISCARD THIS MANUAL

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 9Figure 2.1 General Operating PartsB. Your FireplaceWARNING! DO NOT operate fi re