1Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Models:550TRSI-AUF550TRSILP-AUFOwner’s ManualInstallation and OperationSAI
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1310A. Appliance Certication1 Listing and Code Approvals MODELS:550TRSI-A
11Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Figure 2.1 General Operating PartsB. Your FireplaceWARNING! DO NOT op
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1312D. Clear SpaceWARNING!DONOT place combustible objects in front of the
13Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13I. Lighting Instructions (IPI)1. This appliance is equipped with an
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1314Note: If the module is in LOCK-OUT mode, resetting the circuit brea
15Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13K. After Fireplace is LitInitial Break-in Procedure• The fireplace sho
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1316Glass CleaningFrequency: SeasonallyBy: HomeownerTools Needed: Protecti
17Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13B. Maintenance Tasks-Qualied Service TechnicianThe following tasks must
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1318A. Typical Appliance SystemNOTICE:Illustrations and photos reect typic
19Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13B. Design and Installation ConsiderationsHeat & Glo direct vent gas a
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/132MODELS: 550TRSI-AUF, 550TRSILP-AUFARE SAI GLOBAL APPROVED FOR NATURAL G
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13205 Framing and Clearances A. Selecting Appliance LocationWhen selecting
21Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13B. Constructing the Appliance ChaseA chase is a vertical box-like structu
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1322* MINIMUM FRAMING DIMENSIONSModelsA B C D E F G H I JDVP Pipe SLP PipeRoug
23Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13D. Mantel and Wall ProjectionsWARNING!RiskofFire!Comply with all mini
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1324A. Vent Termination Minimum ClearancesFigure 6.1 Minimum Height From Roo
25Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Figure 6.3 Minimum Clearances for TerminationNOTES: 1. All distances ar
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1326A. Approved PipeThis appliance is approved for use with Hearth & Home
27Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Example: DVP pipe 3 ft. (1 m) min. vertical = 11 ft. (3.35 m) max. horizo
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1328Top Vent - Horizontal Termination - (continued)Figure 7.5Two ElbowsINSTAL
29Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Figure 7.6Three ElbowsH2H1V2V1Note: A 6 in. (152 mm) section of str
3Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Model Name: ___________________________________________ Date purchased/inst
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1330Top Vent - Vertical TerminationThis model is approved to use DVP-Series u
31Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13MODEL550TRSI-AUF550TRSILP-AUFFLUE TERMINATION APPROVALSDVP-TRAP2 HORIZONT
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1332Figure 7.10H1V1V2USE SLP SERIES COMPONENTS ONLYTwo ElbowsTop Vent - Vertic
33Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Figure 7.11Top Vent - Vertical Termination - (continued)Three ElbowsINSTA
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1334Rear Vent - Horizontal TerminationFigure 7.13No ElbowOne 45º ElbowH1Do not
35Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Rear Vent - Horizontal Termination - (continued)Two ElbowsFigure 7.14Figur
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1336Rear Vent - Vertical TerminationOne ElbowFigure 7.16Two ElbowsFigure 7.17V
37Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Rear Vent - Vertical Termination - (continued)Three ElbowsFigure 7.17Thre
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1338A. Pipe Clearances to CombustiblesWARNING!RiskofFire!Maintain air spa
39Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13C. Install the Ceiling FirestopA ceiling restop MUST be used betwe
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/134FOR YOUR SAFETYThis appliance is designed to operate on LPGIF YOU SMELL GAS
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1340Figure 8.5 Attic Insulation ShieldVaulted Ceiling Installation• Remove o
41Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13CAUTION!RiskofCuts,AbrasionsorFlyingDebris.Wear protective gloves
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1342B. Rear VentNOTICE:Once appliance is set up for top or rear venting, it
43Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Figure 9.16 Proper Positioning and Securing of an ApplianceNAILING TABS(BO
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1344Natural Gas Propane Butane550TRSI-AUF 11.13 mm N/A N/A550TRSILP-AUF N/A Fu
45Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1310 Installing Vent Pipe (DVP and SLP Pipe) A. Assemble Vent Sections (D
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1346B. Assemble Vent Sections (SLP Pipe Only)To attach the rst vent componen
47Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13120ºFigure 10.8 Securing Vertical Pipe Sections120ºFigure 10.9 Securing
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/134810 in. (254 mm)12 in. (305 mm)INTERIORWALL SHIELDFigure 10.13 Flue Pipe &
49Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Figure 10.15 Ceiling Firestop (Ceiling Side)Figure 10.16 Attic FirestopC
5Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13 Safety Alert Key:• DANGER!Indicates a hazardous situation which, if n
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1350J. Install Metal Roof Flashing• See minimum vent heights for variou
51Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13CAULKK. Assemble and Install Storm CollarCAUTION!RiskofCuts,Abrasions
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/135211 Gas Information A. Gas Pressure RequirementsWARNING! Risk of Expl
53Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Figure 11.1The gas is introduced to the appliance on the left hand side
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/135412 Electrical Information A. Wiring RequirementsNOTICE:This appliance
55Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13BLUEBROWNGREEN/YELLOWFigure 12.2D. BlowerThese heaters have a factory ins
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1356Hearth & Home Technologies disclaims any responsibility for, and th
57Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/135. Close the housing door. See Figure 12.7.4. Place remote control insi
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1358Figure 12.7 Mounting Remote Control HousingAUX300CE Module Installation•
59Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13FIREPLACE STATUSTHERMOSTAT THERMOSTAT DESIRED TEMP SETTINGFLAME HEIGHTFAN
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/136 = Contains updated information.11 Gas Information A. Gas Pressure Req
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1360About ON Mode• All functions can be accessed when the remote control is i
61Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Adjusting Thermostat• Press the MENU button to activate the menu.• Using
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1362Frequently Asked Questions/TroubleshootingSymptom Possible Cause Correctiv
63Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1313 Finishing A. Mantel and Wall ProjectionsWARNING!RiskofFire!Compl
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1364A. Remove Fixed Glass AssemblySee Section 9.E.B. Remove the Shipping Mat
65Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13E. Log Placement Instructions Log Assembly: LOGS-550TRSAUDCAUTION: Logs a
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1366LOG #4 (SRV278-705): Position log #4 between log #1 and the locating tab o
67Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13LOG #7 (SRV484-703): Place log #7 on the groove in log #2 with its rear to
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/136815 Troubleshooting With proper installation, operation, and maintenance
69Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Troubleshooting (continued)Symptom Possible Cause Corrective Action4. Pilo
7Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13C. Limited Lifetime WarrantyAUSTRALIAN WARRANTY INFORMATIONWarranty inform
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/137016 Reference Materials A. Appliance Dimension DiagramDimensions are act
71Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13B. Maintenance TasksInspect Maintenance TasksDoors 1. Inspect for scratch
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1372C. Vent Components DiagramsFigure 16.3 DVP vent components PipeEffective
73Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13C. Vent Components Diagrams (continued)Figure 16.4 DVP vent componentsDV
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1374DVP-TRAPFLFlashingDVP-HRC-SSDVP-HRC-ZC-SSHorizontal Termination CapFire Ri
75Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13B. Vent Components Diagrams (continued)Figure 16.6 SLP Series Vent Compo
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1376B. Vent Components Diagrams (continued)Figure 16.7 SLP Series Vent Compo
77Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Service PartsBeginning Manufacturing Date: Sept 2010 Ending Manufacturing
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1378Service PartsBeginning Manufacturing Date: Sept 2010 Ending Manufacturing
79Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13Service PartsBeginning Manufacturing Date: Sept 2010 Ending Manufacturing
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/138Warranty Period Heat & Glo Manufactured Appliances and VentingComponent
Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/1380E. Contact InformationPlease contact your Heat & Glo dealer with any
9Heat & Glo • 550TRSI-AUF, 550TRSILP-AUF • 2079-980 Rev. R • 2/13• Non Heat & Glo venting components, hearth components or other access