1Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09
Model:
MTL-Insert
Do not store or use gasoline or other am-
mable vapors and liquids in the vicinity of
this or any other appliance.
What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli-
er’s instructions.
- If you cannot reach your gas supplier, call
the re department.
Installation and service must be performed
by a quali ed installer, service agency, or the
gas supplier.
WARNING: If the information in these
instructions is not followed exactly, a re
or explosion may result causing property
damage, personal injury, or death.
Owners Manual
Installation and Operation
DO NOT DISCARD THIS MANUAL
CAUTION
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer’s instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
Leave this manual with
party responsible for use
and operation.
DO NOT
DISCARD
• Important operating
and maintenance
instructions included.
Read, understand and follow
these instructions for safe
installation and operation.
In the Commonwealth of Massachusetts:
installation must be performed by a licensed plumber
or gas tter;
a CO detector shall be installed in the room where the
appliance is installed.
Installation and service of this appliance should be
performed by quali ed personnel. Hearth & Home
Technologies suggests NFI certi ed or factory trained
professionals, or technicians supervised by an NFI
certi ed professional.
WARNING
This appliance has been supplied with an integral barrier
to prevent direct contact with the xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
DO NOT touch glass until it is cooled
NEVER allow children to touch glass
• Keep children away
CAREFULLY SUPERVISE children in same room as
replace.
Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other ammable
materials.
Keep clothing, furniture, draperies and other ammable
materials away.
Seitenansicht 0
1 2 3 4 5 6 ... 39 40

Inhaltsverzeichnis

Seite 1 - Owner’s Manual

1Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Model:MTL-Insert• Do not store or use gasoline or other fl am-mable vapors and liquids in t

Seite 2 - Congratulations

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09106 6 Installation Preparation Fire Risk.A hearth or hearth extension (if present) must co

Seite 3 - Table of Contents

11Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09A. Venting Components 7 7 Installing Vent Pipe and Appliance The vertical vent terminati

Seite 4

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0912Figure 7.2 CUT AND BEND FLASHING AS NEEDEDTO FIT CHIMNEYSEALANTADHESIVE• Trim chimney t

Seite 5 - Getting Started

13Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09D. Installing Termination CapFor installation of termination cap see minimum vent heights

Seite 6 - TOP VIEW

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0914• Ensure that gas line does not come in contact with outer wrap of appliance. Follow loca

Seite 7 - B. Clearances

15Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Fire hazard. Do NOT change the valve settings.• This valve has been preset at the factory

Seite 8

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0916A. Wiring the Appliance9 9 Electrical Information Note: This appliance must be electrica

Seite 9 - A. Vent Table Key

17Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09B. Optional Junction Box InstallationFigure 9.2 Optional Junction box installationJUNCTI

Seite 10 - Installation Preparation

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0918Figure 9.3 Fan/Rheostat Wire Diagram (Optional)JUNCTION BOXVARIABLE SPEED CONTROLTEMPERAT

Seite 11 - B. Connecting Vent Pipe

19Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09A. Mantel ProjectionsFigure 10.1 shows the minimum vertical and corresponding maximum hori

Seite 12 - Appliance

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/092CongratulationsListing Label Information/LocationModel Name: ______________________________

Seite 13 - Wood Burning

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0920Figure 11.1 Placement of Embers11 11 Appliance Setup A. Remove Shipping MaterialsRemov

Seite 14 - Gas Information

21Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Log Set Assembly: LOGS-SXTE. Positioning the Logs CAUTION: Logs are fragile! Carefully re

Seite 15

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0922LOG #3 (SRV327-703): Position log #3 by locating its slot over the tab on the right front

Seite 16 - A. Wiring the Appliance

23Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09LOG #6 (SRV349-706): Position the "Y" end of log #6 into the cutout on log #4 an

Seite 17

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0924Figure 11.5 Glass AssemblyF. Glass AssemblyRemoving Glass AssemblyThere are two glass lat

Seite 18

25Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Fire Risk.Explosion Risk.Gas may build up while lighting pilot.• Remove glass assembly be

Seite 19 - A. Mantel Projections

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0926B. Lighting ApplianceStanding Pilot Ignition1. Turn off all electric power to the applia

Seite 20 - Appliance Setup

27Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09C. Check Pilot Flame AppearancePilot fl ame must contact the thermocouple and thermopile f

Seite 21 - Log Set Assembly: LOGS-SXT

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0928E. Frequently Asked QuestionsFire Risk.High Temperatures.Keep combustible household items

Seite 22

29Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09A. Standing Pilot Ignition System13 13 Troubleshooting With proper installation, operati

Seite 23

3Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Table of Contents1 Listing and Code Approvals A. Appliance Certifi cation . . . . . . . .

Seite 24 - GLASS ASSEMBLY

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0930Troubleshooting (continued)Symptom Possible Cause Corrective Action3. Continued c. Defecti

Seite 25 - Operating Instructions

31Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0914 14 Maintaining and Servicing Appliance Although the frequency of appliance servicing

Seite 26 - WARNING:

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0932Inspect Maintenance TasksDoors, Surrounds and Fronts1. Assess condition of screen and re

Seite 27 - ADJUSTMENT

33Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Figure 15.1 Appliance Dimensions 15 15 Reference Materials A. Appliance Dimensi

Seite 28 - E. Frequently Asked Questions

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0934B. Vent Kits ComponentsDirect Vent Flex Liner Kits (see Figure 15.2)LINK-DV-30B or (LINK-

Seite 29 - Troubleshooting

35Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Service Parts DiagramMTL-INSERTC. Service PartsBeginning Manufacturing Date: Oct. 2007Endi

Seite 30 - Troubleshooting (continued)

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0936Service Parts DiagramMTL-INSERTService PartsIMPORTANT: THIS IS DATED INFORMATION. When req

Seite 31 - A. Maintenance Tasks

37Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09MTL-INSERTService PartsValve Assembly Parts List Beginning Manufacturing Date: Oct. 2007En

Seite 32 - Inspect Maintenance Tasks

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0938D. Limited Lifetime WarrantyÎ

Seite 33

39Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09D. Limited Lifetime Warranty (continued)Î

Seite 34 - WOODBURNING PIPE

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/094Note: To assure top performance, safety and effi ciency, inserts must be installed with an a

Seite 35 - MTL-INSERT

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0940E. Contact Information- NOTES -___________________________________________________________

Seite 36

5Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Heat & Glo gas inserts are designed for recessed installa-tions into solid fuel masonry

Seite 37

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/096TOP VIEWACB3 3 Fireplace Size Requirements Figure 3.1 Fireplace OpeningNOTE: For actual

Seite 38 - D. Limited Lifetime Warranty

7Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09B. ClearancesFigure 3.2 Clearances to Mantels or other Combustibles above Appliance Fire R

Seite 39

Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/098Fire Risk.Asphyxiation Risk.• Terminations MUST meet minimum clearances.• Exhaust gases a

Seite 40 - DO NOT DISCARD THIS MANUAL

9Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09CAUTIONALL vent specifi cations MUST be followed.• This product is tested and listed to the