1Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Model:MTL-Insert• Do not store or use gasoline or other fl am-mable vapors and liquids in t
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09106 6 Installation Preparation Fire Risk.A hearth or hearth extension (if present) must co
11Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09A. Venting Components 7 7 Installing Vent Pipe and Appliance The vertical vent terminati
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0912Figure 7.2 CUT AND BEND FLASHING AS NEEDEDTO FIT CHIMNEYSEALANTADHESIVE• Trim chimney t
13Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09D. Installing Termination CapFor installation of termination cap see minimum vent heights
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0914• Ensure that gas line does not come in contact with outer wrap of appliance. Follow loca
15Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Fire hazard. Do NOT change the valve settings.• This valve has been preset at the factory
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0916A. Wiring the Appliance9 9 Electrical Information Note: This appliance must be electrica
17Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09B. Optional Junction Box InstallationFigure 9.2 Optional Junction box installationJUNCTI
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0918Figure 9.3 Fan/Rheostat Wire Diagram (Optional)JUNCTION BOXVARIABLE SPEED CONTROLTEMPERAT
19Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09A. Mantel ProjectionsFigure 10.1 shows the minimum vertical and corresponding maximum hori
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/092CongratulationsListing Label Information/LocationModel Name: ______________________________
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0920Figure 11.1 Placement of Embers11 11 Appliance Setup A. Remove Shipping MaterialsRemov
21Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Log Set Assembly: LOGS-SXTE. Positioning the Logs CAUTION: Logs are fragile! Carefully re
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0922LOG #3 (SRV327-703): Position log #3 by locating its slot over the tab on the right front
23Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09LOG #6 (SRV349-706): Position the "Y" end of log #6 into the cutout on log #4 an
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0924Figure 11.5 Glass AssemblyF. Glass AssemblyRemoving Glass AssemblyThere are two glass lat
25Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Fire Risk.Explosion Risk.Gas may build up while lighting pilot.• Remove glass assembly be
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0926B. Lighting ApplianceStanding Pilot Ignition1. Turn off all electric power to the applia
27Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09C. Check Pilot Flame AppearancePilot fl ame must contact the thermocouple and thermopile f
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0928E. Frequently Asked QuestionsFire Risk.High Temperatures.Keep combustible household items
29Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09A. Standing Pilot Ignition System13 13 Troubleshooting With proper installation, operati
3Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Table of Contents1 Listing and Code Approvals A. Appliance Certifi cation . . . . . . . .
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0930Troubleshooting (continued)Symptom Possible Cause Corrective Action3. Continued c. Defecti
31Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0914 14 Maintaining and Servicing Appliance Although the frequency of appliance servicing
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0932Inspect Maintenance TasksDoors, Surrounds and Fronts1. Assess condition of screen and re
33Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Figure 15.1 Appliance Dimensions 15 15 Reference Materials A. Appliance Dimensi
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0934B. Vent Kits ComponentsDirect Vent Flex Liner Kits (see Figure 15.2)LINK-DV-30B or (LINK-
35Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Service Parts DiagramMTL-INSERTC. Service PartsBeginning Manufacturing Date: Oct. 2007Endi
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0936Service Parts DiagramMTL-INSERTService PartsIMPORTANT: THIS IS DATED INFORMATION. When req
37Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09MTL-INSERTService PartsValve Assembly Parts List Beginning Manufacturing Date: Oct. 2007En
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0938D. Limited Lifetime WarrantyÎ
39Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09D. Limited Lifetime Warranty (continued)Î
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/094Note: To assure top performance, safety and effi ciency, inserts must be installed with an a
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/0940E. Contact Information- NOTES -___________________________________________________________
5Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09Heat & Glo gas inserts are designed for recessed installa-tions into solid fuel masonry
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/096TOP VIEWACB3 3 Fireplace Size Requirements Figure 3.1 Fireplace OpeningNOTE: For actual
7Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09B. ClearancesFigure 3.2 Clearances to Mantels or other Combustibles above Appliance Fire R
Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/098Fire Risk.Asphyxiation Risk.• Terminations MUST meet minimum clearances.• Exhaust gases a
9Heat & Glo • MTL-Insert • 2145-900 Rev. G • 6/09CAUTIONALL vent specifi cations MUST be followed.• This product is tested and listed to the